Release Notes

Closed with Code Change in Fabric OS v7.0.0c
Fabric OS v7.0.1 Release Notes v1.0 Page 53 of 67
Defect ID: DEFECT000369430
Technical Severity: High
Summary: Host Discovery issue from edge to edge with VE in BB fabric if EX_Ports are on port 0-3 of
an FX8-24 blade in slot 7 of a DCX-4S.
Symptom: Hosts will not be able to discover targets across the backbone fabric.
Feature: Striker/Spike Platform Services
Function: Routing
Probability: Low
Found in Release: FOS7.0.1
Defect ID: DEFECT000369610
Technical Severity: High
Summary: Emulated FICON Tape Read Channel Program can grow too large, resulting in FICON
Protocol timeouts and aborts
Symptom: FICON Abort during tape read emulation
Feature: FCIP
Function: FCIP I/O
Probability: High
Found in Release: FOS7.0.0
Defect ID: DEFECT000365735
Technical Severity: Medium
Summary: In Extended Fabric sub tab shows the port speed as 0 for ports configured as N16.
Symptom: Configured N16 port speed is not displayed as N16 in the port speed column in Extended
Fabric sub tab for 16G platforms.
Feature: Mgmt Embedded - HTTP
Function: Other
Probability: Medium
Found in Release: FOS7.0.1
Defect ID: DEFECT000367446
Technical Severity: Medium
Summary: diagshow displays incorrect speed value for ports on FCOE10-24 blades
Symptom: diagshow displays the backend 4G ports. customer is expecting to see the front end 10G
ports instead
Feature: Diagnostics
Function: Other
Probability: High
Found in Release: FOS6.4.1
Service Request ID: 668999
Defect ID: DEFECT000374366
Technical Severity: Medium
Summary: Stuck VC detection is being intermittently delayed
Symptom: Stuck VC will be detected, however the detection maybe intermittently delayed
Feature: Bottleneck detection
Function: Other
Probability: Low
Found in Release: FOS7.0.0