Release Notes

Fabric OS v7.0.0c Release Notes v3.0 Page 54 of 67
Closed with Code Change in Fabric OS v7.0.0b - August 24, 2011
This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of
August 24, 2011 in Fabric OS v7.0.0b.
Defect ID: DEFECT000300506
Technical Severity: High
Summary: Observed routing problem after switch running in fmsmode (FICON) changed FID
assignment
Symptom: Connectivity problems in the fabric after changing FID assignment, switch in fabric reported
[RTWR-1002] and [RTWR-1003] RAS log messages.
Workaround: Reboot or power cycle the affected switch or switches
Feature: 8G ASIC Driver
Function: C2 ASIC driver
Probability: Medium
Found in Release: FOS6.4.0
Where Else Fixed: FOS6.4.2 a
Defect ID: DEFECT000341971
Technical Severity: High
Summary: Loop attached device loses secondary disk path after port disable/enable
Symptom: Secondary paths will not appear in the output from disk query commands.
Feature: 8G Platform Services
Function: Other
Probability: Medium
Found in Release: FOS7.0.0
Defect ID: DEFECT000344506
Technical Severity: High
Summary: Port fenced during supportsave
Symptom: Port without errors are fenced during supportsave
Feature: FABRIC WATCH
Function: PORT FENCING
Probability: High
Found in Release: FOS6.4.0
Where Else Fixed: FOS6.4.2 a
Defect ID: DEFECT000347632
Technical Severity: High
Summary: Delays in Name Server observed during FICON CEC IMLs
Symptom: Invalid Attachment and Name Server Query failures may be observed due to delays in
Name Server processing when programming CAM entries for the ASIC.
Feature: 8G ASIC Driver
Function: Other
Probability: Medium
Found in Release: FOS7.0.0