Administrator Guide

When you click Next
on the Configure Ports and Connect Devices window, if Typical Zoning is used,
the final set of connection reservations shown on the window is translated internally into a zoning
scheme that ensures that every correctly connected host device can communicate separately with
every correctly connected storage device. If this is not what you want (for example, if you want to
partition your devices so that each HBA can communicate with some storage devices but not others),
then you should re-run the EZSwitchSetup switch configuration wizard and select Custom Zoning or
Advanced Zoning instead of Typical Zoning.
Use the following procedure to make the physical connections.
1. Install the small form-factor pluggable (SFP) transceivers in the Fibre Channel ports shown
onscreen. (Refer to
FIGURE 16
on page 27.)
a) Remove any protector plugs from the SFP transceivers to be used.
b) Position and insert each SFP transceiver as required (right side up in the top row of ports
and upside down in the bottom row of ports) until it is firmly seated.
c) Close the latching bale.
Setting Up Your Switch
28 EZSwitchSetup Administrator’s Guide
53-1002940-01