Command Reference Guide

752 Fabric OS Command Reference
53-1002746-01
portLedTest
2
-action action
Specifies the LED color. Valid values include the following:
0
Cycle all Port LEDs.
1
Turn Port status LED off.
2
Turn Port status LED amber.
3
Turn Port status LED green.
16
Turn Port speed LED green.
17
Turn Port speed LED amber.
EXAMPLES To test port LEDs on user port 1 use the corresponding value in the "BPt" column of the bladePortMap
command (requires root permission):
switch:admin> portledtest --slot 1 -ports 213
Running portledtest ..............
WARNING:
This test should NOT be aborted in the middle. If aborted, current
blade or the switch (in-case of Pizza box) may become unusable.
Reset the blade or the switch to recover.
PASSED.
To test port LEDs on a Brocade 8000 using default values:
switch:admin> ceeportledtest
PASSED.
SEE ALSO fcipLedTest, itemList, switchDisable, switchEnable