Troubleshooting with the firmwareDownload command
5
Troubleshooting with the firmwareDownload command
A network diagnostic script and preinstallation check is a part of the firmware download procedure.
The script and preinstallation check performs troubleshooting and automatically checks for any
blocking conditions. If the firmware download fails, refer to the Fabric OS Message Reference for
details about error messages. Also refer to, “Considerations for downgrading firmware” on
page 56.
ATTENTION
Do not run mixed firmware versions on CPs.
If a firmware download fails in a director, the firmwareDownload command synchronizes the
firmware on the two partitions of each CP by starting a firmware commit operation. Wait at least 15
minutes for this commit operation to complete before attempting another firmware download.
If the firmware download fails in a director or enterprise-class platform, the CPs may end up with
different versions of firmware and are unable to achieve HA synchronization between the two
blades. In such cases, issue the firmwareDownload -s command on the standby CP; the single
mode (-s) option allows you to upgrade the firmware on the standby CP to match the firmware
version running on the active CP. This situation can also occur during a CP replacement in which
the replacement CP has a lower firmware version. HA should be disabled and the firmware should
be updated on the replacement CP before any other operations are considered.
Then reissue the firmwareDownload command to download the desired firmware version to both
CPs. For example, if CP0 is running Fabric OS v7.1.0 on the primary and secondary partitions, and
CP1 is running Fabric OS v7.2.0 on the primary and secondary partitions, then synchronize them by
issuing the firmwareDownload command.
NOTE
Some of the messages include error codes (as shown in the following example). These error codes
are for internal use only and you can disregard them.
Port configuration with EX ports enabled along with trunking for port(s) 63, use
the portCfgEXPort, portCfgVEXPort, and portCfgTrunkPort commands to remedy this.
Verify blade is ENABLED. (error 3)
Gathering additional information
You should follow these best practices for firmware download before you start the procedure:
Keep all session logs.
Enter the supportSave or the supportShow command before and after entering the
firmwareDownload command.
If a problem persists, package together all of the information (the Telnet session logs and serial
console logs, output from the supportSave command) for your switch support provider. Make
sure you identify what information was gathered before and after issuing the
firmwareDownload command.