Release Notes

Close with Code Change in Fabric OS v7.0.2
Fabric OS v7.0.2 Release Notes v1.0 Page 35 of 99
Defect ID:
DEFECT000368909
Technical Severity:
Medium
Summary:
AG is not registering descriptor and creating /var/log/ag_desc.txt
Symptom:
Switch experiences excessive CF usage due to generation of /var/log/ag_desc.txt.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Management Services
Reported In Release:
FOS6.4.1
Service Request ID:
671597
Defect ID:
DEFECT000369660
Technical Severity:
Medium
Summary:
Enhanced SERDES tuning to address CRC with good EOF
Symptom:
CRC with good EOF reported with following platform, blade, port combination.
On DCX, when FC8-48 in slot 3, 3/55<->5/18
On DCX-4s, When FC8-48 in slot2, 3/56 <->2/40
On DCX, with FC8-64 in slot12, 5/151<->12/33
On DCX-4S, with FC8-16 in slot1, slot2
On DCX, with FC8-64 in slot2, 8/80 <->2/155
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Medium
Function:
ASIC Driver
Reported In Release:
FOS6.4.2
Service Request ID:
663795
Defect ID:
DEFECT000370106
Technical Severity:
Medium
Summary:
Enabling track changes in native mode keeps feature active when AG mode is enabled but CLI no
longer works
Symptom:
Customer enabled track changes using trackchangesset 1 when switch was in native mode. When
switch mode is changed from native to AG, track change stays enabled but trackchange CLIs no
longer works in AG mode.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Access Gateway
Reported In Release:
FOS6.4.2
Service Request ID:
673067
Defect ID:
DEFECT000373880
Technical Severity:
Medium
Summary:
Issue observed with perfcfgrestore command
Symptom:
If a number of rwmonitors are created for a particular port using 'perfaddrwmonitor' command and
these are deleted, then in some situations the 'perfcfgrestore' will not restore all of the monitors
previously created.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
System Performance
Reported In Release:
FOS6.4.2
Service Request ID:
680497
Defect ID:
DEFECT000374689
Technical Severity:
Medium
Summary:
Software 'verify' error detected when portstatsshow was executed with invalid index (999) and the -f
option
Symptom:
When survey a fabric , the invalid index is passed in and triggers switch panic when too many verifies
is displayed on console.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Diagnostics
Reported In Release:
FOS6.4.2
Service Request ID:
683277