Release Notes

Close with Code Change in Fabric OS v7.0.2
Fabric OS v7.0.2 Release Notes v1.0 Page 36 of 99
Defect ID:
DEFECT000374751
Technical Severity:
Medium
Summary:
Security vulnerability check for CVE-2011-3192 fails on switches running on FOS prior to v7.0.2
Symptom:
When the vulnerability is explored, it may trigger increase in memory and CPU usage and lead to a
Denial of Service condition with Httpd server.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Medium
Function:
Web Management
Reported In Release:
FOS7.0.0
Service Request ID:
683571
Defect ID:
DEFECT000377420
Technical Severity:
Medium
Summary:
ifmodeset is set to default after firmware upgrade
Symptom:
Management ports went down after code upgrade.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Firmware Download
Reported In Release:
FOS6.3.2
Service Request ID:
683983
Defect ID:
DEFECT000377806
Technical Severity:
Medium
Summary:
restoring snmp configurations over writing AAA LDAP Settings
Symptom:
When trying to replicate SNMP settings alone from one switch to another switch using BNA, AAA
settings also getting replaced.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
High
Function:
OS: Configuration
Reported In Release:
FOS6.4.1
Service Request ID:
FromPM
Defect ID:
DEFECT000378374
Technical Severity:
Medium
Summary:
F_Port trunk area configuration may be lost in switches when upgrading to FOS 6.4.x
Symptom:
If there were F_Port trunk configured during switch running at FOS v6.1, Then selected F_Port trunk
configuration performed when FOS v6.2.x/v6.3.x was installed may be lost after an upgrade from
FOS v6.2.x/v6.3.x to FOS v6.4.x.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Fabric Services
Reported In Release:
FOS6.4.2
Service Request ID:
689353
Defect ID:
DEFECT000378874
Technical Severity:
Medium
Summary:
Unexpected behavior of End to End (EE) monitor
Symptom:
Traffic reported with EE monitor while there is no traffic due to counters are not getting initialized
when configure EE monitor on port with no traffic.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Diagnostics
Reported In Release:
FOS6.4.2
Service Request ID:
690341
Defect ID:
DEFECT000379840
Technical Severity:
High
Summary:
fabric with ETIZoning, data stops flowing when switching zoning enforcement "Hard-Port" <-->
"Hard-Wwn"
Symptom:
changing zoning enforcement from wwn <--> D,I <--> session based will cause some traffic to stop
flowing. lasers must be toggled to correct the issue
Workaround:
User can toggle the port (disable/enable) to correct the issue.
Risk of Fix:
Low
Feature:
FC Services
Probability:
High
Function:
Name Server
Reported In Release:
FOS7.0.1