Release Notes

Fabric OS v7.0.0c Release Notes v3.0 Page 51 of 67
Closed with Code Change in Fabric OS v7.0.0c
This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of
November 18, 2011 in Fabric OS v7.0.0c
Defect ID: DEFECT000354348
Technical Severity: High
Summary: Not receiving the RAS log Cx-5021 message for front port partial credit loss on an EX-Port
Symptom: Customer will be unaware if EX_Ports are leaking credit.
Feature: 8G FCR
Function: FCR Daemon
Probability: Low
Found in Release: FOS7.0.0
Defect ID: DEFECT000364137
Technical Severity: High
Summary: FabricWatch Port Class is not monitoring ICL ports. E-Port Class monitors are monitoring
ICL ports.
Symptom: ICL Ports will not report any threshold warnings and will not be fenced for Port Class
attributes.
Feature: FABRIC WATCH
Function: PORT FENCING
Probability: High
Found in Release: FOS7.0.0
Defect ID: DEFECT000364799
Technical Severity: High
Summary: After downgrading from v7.0.0 to v6.4.x, a route rebalance or recalculation will cause some
ICL paths to be blocked.
Symptom: Connectivity between devices lost after route change.
Workaround: Disable all ICL ports and then enable all ICL ports.
Feature: UNDETERMINED
Function: UNDER REVIEW
Probability: High
Found in Release: FOS6.4.2
Defect ID: DEFECT000364945
Technical Severity: High
Summary: Unable create 4th tunnel with crossport circuits in chassis with multiple FX8-24 blades.
Symptom: Unable create more than three tunnels with crossport circuit configuration in a chassis with
multiple FX8-24 blades.
Feature: FCIP
Function: Other
Probability: High
Found in Release: FOS7.0.0