Developers Guide

80 Fabric OS Troubleshooting and Diagnostics Guide
53-1003141-01
Gathering additional information
9
If they are in the same zone, perform the following tasks:
Enter the portCamShow command on the host port to verify that the target is present.
Enter the portCamShow command on the target.
Enter the nsZoneMember command with the port ID for the zoned devices on the host
and target to determine whether the name server is aware that these devices are
zoned together.
3. Resolve zoning conflicts by putting the devices into the same zoning configuration.
4. Verify that no configuration is active by using the cfgActvShow command. Enter the defZone
--
show command to display the current state of the zone access mode
and the access level.
The defZone command sets the default zone access mode to No Access
.
switch:admin> defzone
--
show
Default Zone Access Mode
committed - No Access
transaction - No Transaction
Refer to “Zone conflicts” on page 75 for additional information.
Gathering additional information
Collect the data from a supportSave -n command. Then collect the data from the cfgTransShow
command. For the port having the problem, collect the data from the filterPortShow port command.