Release Notes

Closed defects with code change in Fabric OS v7.2.0
Fabric OS v7.2.0a Release Notes v1.0 Page 76 of 93
Defect ID:
DEFECT000444171
Technical Severity:
High
Summary:
Data buffer is too small for holding frames header in error condition
Symptom:
Kernel panic on BR8000 switch with FCOE when sending several iterations of maximum number of
FDISCs continually.
Risk of Fix:
Low
Probability:
Low
Feature:
CEE-FCOE
Function:
FCOE DRIVER
Reported In Release:
FOS6.4.3
Service Request ID:
1111262
Defect ID:
DEFECT000444288
Technical Severity:
Medium
Summary:
Generate an alert if timeout frame discards and congestion are detected at the same time
Symptom:
No bottleneck alert is generated even if frames are already being discarded due to timeout.
Risk of Fix:
Medium
Probability:
High
Feature:
Bottleneck detection
Function:
Other
Reported In Release:
FOS7.1.0
Defect ID:
DEFECT000444752
Technical Severity:
Medium
Summary:
Switch has a large tracedump file of 30M and run out of CF space
Symptom:
Small non-chassis switches hang during bootup after pre-allocation of a large tracefile from Compact
Flash.
Risk of Fix:
Low
Probability:
Low
Feature:
FOS Software
Function:
Fabric Services
Reported In Release:
FOS6.2.2
Service Request ID:
1116474
Defect ID:
DEFECT000445485
Technical Severity:
High
Summary:
Assert reboot and failover on normal traffic
Symptom:
SNMP received a warmstart trap and CP status changed to failed. Switch failed over and rebooted
failed CP.
Risk of Fix:
Low
Probability:
Low
Feature:
4G Platform Services
Function:
FOS Kernel Drivers
Reported In Release:
FOS6.4.1
Service Request ID:
1144739
Defect ID:
DEFECT000445644
Technical Severity:
High
Summary:
BES went into low memory state because of “Continuous polling from BNA”
Symptom:
BES CLI Commands are failing - Operation failed: BES/FS8-18 blade is not present or up
Risk of Fix:
Medium
Probability:
Medium
Feature:
FOS Software
Function:
Encryption
Reported In Release:
FOS7.0.2
Service Request ID:
1145987
Defect ID:
DEFECT000445729
Technical Severity:
High
Summary:
QSFP LED state inconsistent with port state on the corresponding 4 channels (ports)
Symptom:
Two symptoms observed:
1. QSFP's LED light is OFF while all four of the ICL based E-Ports on that single QSFP are online.
2. QSFP's LED light is blinking Amber when no QSFP installed.
Risk of Fix:
Low
Probability:
Medium
Feature:
16G Platform Services
Function:
Other
Reported In Release:
FOS7.1.0