Release Notes

Closed defects with code change in Fabric OS v7.2.0
Fabric OS v7.2.0a Release Notes v1.0 Page 77 of 93
Defect ID:
DEFECT000445814
Technical Severity:
Medium
Summary:
Configuration download failure when downloading fabric watch settings
Symptom:
After configuration download from CLI or using BNA to do partial fabric watch data replication,
Bottleneck configurations were removed from the switch.
Risk of Fix:
Low
Probability:
Medium
Feature:
FOS Software
Function:
Management Services
Reported In Release:
FOS7.0.0
Service Request ID:
1137933
Defect ID:
DEFECT000446004
Technical Severity:
High
Summary:
7800 Tunnel in DwnPend state after making change to committed rate
Symptom:
7800 Tunnel enters DwnPend state after configuration change is made. An IPC error is reported
during subsequent attempts to delete the tunnel.
Risk of Fix:
Low
Probability:
Medium
Feature:
FOS Software
Function:
FCIP
Reported In Release:
FOS7.0.1
Service Request ID:
1147343
Defect ID:
DEFECT000446429
Technical Severity:
High
Summary:
ASIC entries are not being cleared upon HA processing leading to server issues.
Symptom:
Observer non-responsive host paths on an server with server eventually crashing. Switch does not
forward any SCSI task management commands
Risk of Fix:
Low
Probability:
Low
Feature:
FOS Software
Function:
Fabric Services
Reported In Release:
FOS7.1.0
Service Request ID:
1143385
Defect ID:
DEFECT000446834
Technical Severity:
Medium
Summary:
When ICL Port Fencing is enabled, port enable/disable button in WT displays UI anomalies.
Symptom:
WT presents incorrect options for enable/disable of ports.
Risk of Fix:
Low
Probability:
Medium
Feature:
WebMgmt
Function:
Other
Reported In Release:
FOS7.1.0
Defect ID:
DEFECT000446858
Technical Severity:
Medium
Summary:
In a heavily congested fabric, if a HAfailover happens when a backend port is reporting frame
timeout, switch falsely identifies stuck VC and performs link reset.
Symptom:
Switch continuously reports RASLOG “C2-1014, Link Reset” on backend port, and under rare
occasion, observed switch panic.
Risk of Fix:
Medium
Probability:
Medium
Feature:
4G Platform Services
Function:
FOS Kernel Drivers
Reported In Release:
FOS7.0.2
Service Request ID:
1148619,1132068
Defect ID:
DEFECT000447216
Technical Severity:
High
Summary:
Access Gateway does not respond to FLOGI from host
Symptom:
Access gateway does not respond to the FLOGI issued by the host adapter with ExtLinkRply Accept
Risk of Fix:
Low
Probability:
Medium
Feature:
Access Gateway Services
Function:
Other
Reported In Release:
FOS7.1.0