174 Fabric OS Message Reference
53-1002929-01
BL-1016
5
BL-1016
Message Blade port <port number> in slot <slot number> failed to enable.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the specified blade port could not be enabled.
Recommended
Action
Make sure that the blade is seated correctly.
If the blade is seated correctly, execute the diagPost command to make sure that Power-On Self-Test
(POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or
have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware
problems.
If the message persists, replace the blade.
BL-1017
Message Slot <slot number> Initializing...
Message Type LOG
Severity INFO
Probable Cause Indicates that the slot has started initializing the ports.
Recommended
Action
No action is required.
BL-1018
Message Slot <slot number> Initialization completed.
Message Type LOG
Severity INFO
Probable Cause Indicates that the slot has completed initializing the ports.
Recommended
Action
No action is required.