178 Fabric OS Message Reference
53-1002929-01
BL-1028
5
BL-1028
Message Switch faulted; internal processor was reset before switch init completed.
Message Type LOG
Severity CRITICAL
Probable Cause Indicates that the switch internal processor was reset before the initialization completed.
Recommended
Action
Reboot or power cycle the switch using the slotPowerOff and slotPowerOn commands.
If the message persists, replace the switch.
BL-1029
Message All ports on the switch will be reset as part of the firmware upgrade.
Message Type LOG
Severity INFO
Probable Cause Indicates that a recent firmware upgrade caused the switch internal processor firmware to be upgraded
and resulted in a cold upgrade. As part of the upgrade, all the datapath elements were reset.
Recommended
Action
No action is required.
BL-1030
Message All GigE/FCIP/Virtualization/FC Fastwrite ports on the switch will be reset as
part of the firmware upgrade.
Message Type LOG
Severity INFO
Probable Cause Indicates that a recent firmware upgrade caused the switch internal processor firmware to be upgraded
and resulted in the cold upgrade. As part of the upgrade, all Gigabit Ethernet, Fibre Channel over IP
(FCIP), virtualization data elements, and FC Fastwrite ports were reset.
Recommended
Action
No action is required.