Reference Guide

Fabric OS Message Reference 287
53-1002929-01
EM-1008
5
EM-1008
Message Unit in <Slot number or Switch> with ID <FRU Id> is faulted, it is incompatible
with the <type of incompatibility> configuration, check FOS firmware version as a
possible cause.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that a blade inserted in the specified slot or the switch (for non-bladed switches) is not
compatible with the platform configuration (includes the firmware version) or the switch configuration.
The blade is faulted.
Recommended
Action
If the blade is incompatible, upgrade the firmware or replace the blade and make sure the replacement
blade is compatible with your control processor (CP) type and firmware.
If the incompatibility is with the logical switch configuration, change the configuration by using the lscfg
command to be consistent with the blade type, or remove the blade.
EM-1009
Message <FRU Id> powered down unexpectedly.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the environmental monitor (EM) received an unexpected power-down notification from the
specified field-replaceable unit (FRU). This may indicate a hardware malfunction in the FRU.
Recommended
Action
Reseat the FRU. If the problem persists, replace the FRU.
EM-1010
Message Received unexpected power down for <FRU Id> But <FRU Id> still has power.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the environmental monitor (EM) received an unexpected power-down notification from the
specified field-replaceable unit (FRU). However, the specified FRU still appears to be powered up after
four seconds.
Recommended
Action
Reseat the blade. If the problem persists, replace the blade.