Reference Guide

288 Fabric OS Message Reference
53-1002929-01
EM-1011
5
EM-1011
Message Received unexpected power down for <FRU Id>, but cannot determine if it has power.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the environmental monitor (EM) received an unexpected power-down notification from the
specified field-replaceable unit (FRU). However, after four seconds, it cannot be determined if it has
powered down or not.
Recommended
Action
Reseat the blade. If the problem persists, replace the blade.
EM-1012
Message <FRU Id> failed <state> state transition, unit faulted.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that a switch blade or non-bladed switch failed to transition from one state to another. It is
faulted. The specific failed target state is displayed in the message. There are serious internal Fabric OS
configuration or hardware problems on the switch.
Recommended
Action
Reseat the specified field-replaceable unit (FRU).
If the problem persists, restart or power cycle the switch.
Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power
cycle the blade by using the slotPowerOff and slotPowerOn commands or have the blade's ejector
switch cycled to run POST and verify that the blade does not have any hardware problems.
If the problem still persists, replace the FRU.
EM-1013
Message Failed to update FRU information for <FRU Id>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the environmental monitor (EM) was unable to update the time alive or original equipment
manufacturer (OEM) data in the memory of a field-replaceable unit (FRU).
Recommended
Action
If you executed the fruInfoSet command, execute the command again; otherwise, the update is
automatically attempted again. If it continues to fail, reseat the FRU.
If the problem persists, replace the FRU.