Reference Guide

Fabric OS Message Reference 455
53-1002929-01
FW-1010
5
FW-1010
Message <Label>, is below low boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the power supply is faulty. The power supply is not producing enough power.
Recommended
Action
Verify that you have installed the power supply correctly and that it is correctly seated in the chassis. If
the problem persists, replace the faulty power supply.
FW-1011
Message <Label>, is above high boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Message Type LOG
Severity INFO
Probable Cause Indicates that the power supply is functioning properly.
Recommended
Action
Set the high boundary above the normal operation range.
FW-1012
Message <Label>, is between high and low boundaries(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
Message Type LOG
Severity INFO
Probable Cause Indicates that the power supply counter changed from a value outside of the acceptable range to a value
within the acceptable range.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.