Reference Guide

586 Fabric OS Message Reference
53-1002929-01
IPS-1004
5
IPS-1004
Message Port Config Mode Mismatch slot (<slot>) port(ge<port>): current mode is (<current
mode>).
Message Type LOG
Severity WARNING
Probable Cause Indicates that configured port mode is different from the intended use.
Recommended
Action
Change the port configuration (by deleting configured FCIP tunnels or iSCSI sessions) to return the port
mode to neutral before attempting to configure the port for a different mode or use.
IPS-1005
Message Tunnel Authorization Failure for slot (<slot>) port(ge<port>) tunnel ID(<tunnel
number>) reason (<reason>).
Message Type LOG
Severity WARNING
Probable Cause Indicates that tunnel setup failed because of an authorization failure from the remote side. A reason for
such a failure could be a WWN mismatch.
Recommended
Action
Change the tunnel configuration on one side of the tunnel to authorize the remote side to set up the
tunnel.
IPS-1006
Message Tunnel Configuration Mismatch for slot (<slot>) port(<port>) tunnel ID(<tunnel
number>) reason (<reason>).
Message Type LOG
Severity WARNING
Probable Cause Indicates that tunnel setup failed because of a configuration mismatch between the two ends. The
reason field indicates the cause for configuration mismatch.
Recommended
Action
Change the tunnel configuration on one side of the tunnel to match that of the other side to set up the
tunnel.