Reference Guide

878 Fabric OS Message Reference
53-1002929-01
SYSM-1001
5
SYSM Messages
SYSM-1001
Message No memory.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates the switch has run out of system memory.
Recommended
Action
Run the memShow command to view the switch memory usage.
Reboot or power cycle the switch.
Run the supportFtp command (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
SYSM-1002
Message <number>, Switch: <Switch number>.
Message Type LOG
Severity INFO
Probable Cause Indicates a user has executed either the switchShutdown or switchReboot command. All services are
brought down for a logical switch.
Recommended
Action
No action is required if the switchShutdown or switchReboot command was executed intentionally. If
the switchShutdown command was run, you must run the switchStart command to restart traffic on the
logical switch.
SYSM-1003
Message <number>, Switch: <start reason>.
Message Type LOG
Severity INFO
Probable Cause Indicates the user executed the switchStart or switchReboot command. All services are brought back
up after a temporary shutdown of the logical switch.
Recommended
Action
No action is required if the switchStart command was executed intentionally. Because reinitializing a
switch is a disruptive operation and can stop I/O traffic, you may have to stop and restart the traffic during
this process.