Brocade Fabric OS v7.2 v7.2.1e Release Notes v1.0 April 17, 2015 Document History Document Title Summary of Changes Publication Date Brocade Fabric OS v7.2.1e Release Notes v1.
© 2015 Brocade Communications Systems, Inc. All Rights Reserved. ADX, AnyIO, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, ICX, MLX, MyBrocade, OpenScript, VCS, VDX, and Vyatta are registered trademarks, and HyperEdge, The Effortless Network, and The On-Demand Data Center are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names mentioned may be trademarks of their respective owners.
Contents Overview ...................................................................................................................................................... 5 Resolution of Important Defects ............................................................................................................................. 5 This release contains the following important fixes. .............................................................................................
Port Statistics ......................................................................................................................................................... 29 Virtual Fabrics ........................................................................................................................................................ 29 WebTools ..............................................................................................................................................................
Overview Fabric OS (FOS) v7.2.1e is a patch release based on FOS v7.2.1d. All hardware platforms and features supported in FOS v7.2.1 are also supported in FOS v7.2.1e. This release contains fixes for many defects. This release also merge in the support for long distance 16G optical cable QSFP that extends the ICL connectivity up to two kilometers (km). Resolution of Important Defects This release contains the following important fixes.
Optionally Licensed Software Fabric OS v7.2 includes all basic switch and fabric support software, as well as optionally licensed software that is enabled via license keys. Optionally licensed features include: Brocade Ports on Demand—Allows customers to instantly scale the fabric by provisioning additional ports via Demand license key upgrade. (Applies to select models of switches).
Adaptive Networking with QoS—Adaptive Networking provides a rich framework of capability allowing a user to QoS ensure high priority connections obtain the bandwidth necessary for optimum performance, even in congested environments. The QoS SID/DID Prioritization and Ingress Rate Limiting features are the first components of this license option, and are fully available on all 8Gb and 16Gb platforms. Note : With FOS v7.
10GbE FCIP/10 FCIP/10G 10G Fibre Channel – This license enables the two 10GbE ports on the FX8-24 and/or the 10G FC capability on FC16-xx blade ports supported on DCX 8510 platforms. On the Brocade 6510, Brocade 6520 this license enables 10G FC ports.
Temporary License Support The following licenses are available in FOS v7.
Supported Switches FOS v7.2.1 supports the following existing platforms: • 300, 5100, 5300, 7800, VA-40FC, Brocade Encryption Switch, DCX, DCX-4S • 6505, 6510, 6520, DCX 8510-8, DCX 8510-4 • FC16-32, FC16-48, FC8-32E, FC8-48E, FC8-64, FX8-24, FS8-18 on DCX 8510-8/DCX 8510-4 • FC8-16, FC8-32, FC8-48, FC8-64, FX8-24, FS8-18, FCOE10-24 on DCX/DCX-4S • 5410, M5424, 5430, 5450, 5480, 5470, 5460, NC-5480 • Support merged to FOS v7.2.
• Switch operating system version • Error numbers and messages received • supportSave command output and associated files o For dual CP platforms running FOS v6.
FOS Migration Considerations This section contains important details to consider before migrating to or from this FOS release. FOS Upgrade and Downgrade Special Considerations DCX/DCX-4S units running any FOS v7.1.x or FOS v7.2.0x can be non-disruptively upgraded to FOS v7.2.1e. This upgrade is non-disruptive to both FC and FCoE traffic (when using FCOE10-24 blades). Any firmware activation on Brocade 7800, or DCX, DCX-4S, DCX 8510-8, DCX 8510-4 with FX8-24 will disrupt I/O traffic on the FCIP links.
Important Notes This section contains information that you should consider before you use this Fabric OS release. Brocade Network Advisor Compatibility Brocade Network Advisor greatly simplifies the steps involved in daily operations while improving the performance and reliability of the overall SAN and IP networking environment. Brocade Network Advisor unifies, under a single platform, network management for SAN, LAN and converged networks.
Brocade Network Advisor 12.1.6 supports launching WebTools with JRE 1.7u45, JRE 1.7u51[Windows], and JRE 1.7u67 [Linux]. SMI Compatibility • It is important to note that host SMI-S agents cannot be used to manage switches running FOS v7.2. If users want to manage a switch running FOS v7.2 using SMI-S interface, they must use Brocade Network Advisor’s integrated SMI agent.
MultiMulti-Protocol Router Interoperability nteroperability Brocade 7500 and FR4-18i blade V6.2.2 and higher 4 6 8 McDATA SANRouters 1620 and 2640 Not Supported NOS (VDX Platform) Interop Interoperability nteroperability Brocade VDX6710, VDX6720, VDX6730 NOS v2.1.1 or later7 Brocade VDX8770 NOS 3.
SNMP Support Starting with FOS v7.2.0, the Fabric OS MIB Reference document is not updated. You can obtain the latest MIBs from the downloads area of MyBrocade site after logging in. For information about SNMP support in Fabric Operating System (FOS) and how to use MIBs, see the Fabric OS Administrator’s Guide. Obtaining the MIBs You can download the MIB files required for this release from the downloads area of the MyBrocade site.
Fabric OS v7.2 software is fully qualified and supports the blades for the DCX/DCX-4S noted in the following table: DCX/DCXDCX/DCX-4S Blade Support Matrix 16-, 32-, 48- and 64-port 8Gbit port blades (FC8-16, FC8-32, FC8-48, FC8-64) Supported with FOS v6.0 and above (FC8-64 requires FOS v6.4) with any mix and up to 8/4 of each. No restrictions around intermix. FC10-6 Not supported on FOS v7.1 or later Intelligent blade Up to a total of 8/4 intelligent blades.
Fabric OS v7.2 software is fully qualified and supports the blades for the DCX 8510-8 and DCX 8510-4 noted in the table below. DCX 85108510-8/DCX 85108510-4 Blade Support Matrix FC16-32, FC16-48 16G FC blades FOS v7.0 or later. FC8-64 64 port 8Gbit port blade With any mix and up to 8/4 of each. No restrictions around intermix. Note: FC8-16, FC8-32, FC8-48 blades are not supported on DCX 8510 platforms. FC8-32E, FC8-48E FOS v7.0.1 or later. Intelligent blade Up to a total of 8/4 intelligent blades.
Power Supply Requirements for Blades in DCX/DCXDCX/DCX-4S Blades Type of Blade FC10-61, FC816, FC8-32, FC 8-48, FC864 Port Blade FR4-18i1 FS8-18, FX8-24, FCOE10-24 DCX/DCXDCX/DCX-4S DCX/DCXDCX/DCX-4S @110 VAC (Redundant configurations) @200-240 VAC (Redundant configurations) 2 Power Supplies 2 Power Supplies Intelligent Blade Not Supported 2 Power Supplies Intelligent Blade Not Supported DCX: 2 or 4 Power Supplies Comments Distribute the Power Supplies evenly to 2 different AC connections
Typical Power Supply Requirements Guidelines for Blades in DCX 85108510-8 (For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications in the 85108510-8 Backbone Hardware Reference Manual) Configured Number of Ports Blades Blades Type of Blade DCX 85108510-8 @110 VAC (Redundant configurations) DCX 85108510-8 @200@200-240 VAC (Redundant configurations) Comments Any combination of 8Gb or 16Gb ports with QSFP ICLs FC8-64, FC16-32, FC8-32E
Typical Power Supply Requirements Guidelines for Blades in DCX 85108510-8 (For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications in the 85108510-8 Backbone Hardware Reference Manual) Configured Number of Ports Blades Blades Type of Blade DCX 85108510-8 @110 VAC (Redundant configurations) DCX 85108510-8 @200@200-240 VAC (Redundant configurations) Comments 384 16Gb ports + QSFP ICLs FC16-32, FC16-48 Port Blade Not Supported 4 Powe
Typical Power Supply Requirements Guidelines for Blades in DCX 85108510-4 (For specific calculation calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications in the 85108510-4 Backbone Hardware Reference Manual) Configured Blades Number of Ports Type of Blade DCX 85108510-4 @110 VAC (Redundant configurations) DCX 85108510-4 @200@200-240 VAC (Redundant configurations) Comments 96 ports max with QSFP ICLs FC16-32, FC8-32E Port Blade 2 Power Supplie
• If FOS v7.2 or later is factory installed (or net installed), Adaptive Networking features are always available. This matches the behavior of the Brocade 6520 and all products shipping with prior versions of FOS and with the Adaptive Networking license factory installed. • Ports will come up in AE mode by default • If the remote port supports QOS and is not explicitly disabled, the link will come up in QOS mode. Otherwise, the link will come up in normal mode.
Gen 5 platforms and blades are capable of setting an EHT value on an individual port basis. On 8G platforms EHT is set on an ASIC-wide basis, meaning all ports on a common ASIC will have the same EHT setting. Extra care should be given when configuring EHT on 8G platforms or Gen 5 platforms with 8G blades to ensure E_Ports are configured with an appropriate Hold Time setting. When using Virtual Fabrics and creating a new Logical Switch when running FOS v7.1.
• Hot Code Load from FOS v7.1.x to FOS v7.2 or later is supported. Cryptographic operations and I/O will be disrupted but other layer 2 FC traffic will not be disrupted. • When disk and tape CTCs are hosted on the same encryption engine, re-keying cannot be done while tape backup or restore operations are running. Re-keying operations must be scheduled at a time that does not conflict with normal tape I/O operations.
FCoE/DCB/CEE (FCOE10-24) • When upgrading a DCX/DCX-4S with one or more FCOE10-24 blades from FOS v6.x to FOS v7.0.0 or later, the user should carefully review Chapter 5 of the FOS v7.0.0 Converged Enhanced Ethernet Administrator’s Guide. • Ethernet L2 traffic with xSTP Hello timer set to less than or equal to 3 seconds may experience momentary traffic disruption during HA failover. • Hot plugging a CP with firmware level less than FOS v6.3.
the same OUI will have unique last 3 bytes in WWN). However, if the participating switches have different OUIs but identical last three bytes in the switch WWNs, then the merge logic will fail to guarantee uniqueness of login group names. This will result in one of the login groups being dropped from the configuration. This means, no device can login to the login group that is dropped as a result of this name conflict. Users must create a new login group with a non-conflicting name to allow device logins.
• The FC8-48 and FC8-64 blade support attachment of loop devices. • Virtual Fabrics must be enabled on the chassis and loop devices may only be attached to ports on a 48-port or 64-port blade assigned to a non-Default Logical Switch operating with the default 10bit addressing mode (they may not be in the default Logical Switch). • A maximum of 144 ports may be used for connectivity to loop devices in a single Logical Switch within a chassis in 10-bit dynamic area mode on DCX-4S.
Port Mirroring • Port Mirroring is not supported on the Brocade 7800. Port Statistics • On 16G capable ports, the enc_in (number of encoding errors inside of frames) and enc_out (number of encoding errors outside of frames) counters will not be updated when a port is operating at either 10G or 16G speed. This is due to the different encoding scheme used at 10G and 16G speeds when compared to 8G/4G/2G speeds.
• FOS v7.3.0 FOS versions before the above listed ones do not support JRE 1.7.0 update 76. Users can use the following workaround on a computer launching WebTools. 1. Go to C:\Program Files\Java\jre7\lib\security 2. Edit java.security file and change the value to 256 from 1024 for jdk.certpath.disabledAlgorithms=MD2, RSA keySize < 1024 Zoning • Support for up to 2MB zone database in a fabric with only DCX/DCX-4S/DCX8510 systems.
chassisshow command has a “Power Usage (Watts):” field that shows the actual power consumed in real-time on 16G blades. • Class 3 frames that have been trapped to CPU will be discarded in the following scenarios on DCX/DCX-4S/DCX 8510 during the following conditions: • HA failover on DCX/DCX-4S/DCX 8510 platforms while running FOS v7.0 or later firmware • Firmware upgrade from v7.0 to a later release on Brocade 300, 5100, VA-40FC, 5300, 6510 • Firmware upgrade from v7.0.
Defects Closed with Code Change in Fabric OS v7.2.1e Defect ID: DEFECT000491910 Technical Severity: Medium Probability: High Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.2.1 Technology Area: Logging Symptom: SNMP query connUnitPortStatCountBBCreditZero or CLI portstats64show could display an unexpected large value for tim64_txcrd_z counter in a very brief time Condition: This issue will be seen when there is a FC traffic slowness in fabric and statistic counter wraps.
Closed with Code Change in Fabric OS v7.2.1e Defect ID: DEFECT000523367 Technical Severity: High Probability: High Product: FOS Technology: FICON Reported In Release: FOS7.1.0 Technology Area: FICON CUP Symptom: MVS displays messages IOS078I & IOS079I timeouts. Condition: In a very busy switch, with the CUP processing CCWs from multiple Host LPARs, e.g. many LPARS independently collecting RMF statistics from the CUP.
Closed with Code Change in Fabric OS v7.2.1e Defect ID: DEFECT000531571 Technical Severity: High Probability: Low Product: FOS Technology: Traffic Management Reported In Release: FOS7.0.0 Technology Area: Port Bring-up Symptom: Port blade remained faulted after a power event. Condition: This may occur in a rare scenario, when a CP has been running for a duration and memory has been utilized to cache file system buffers and a blade is power cycled.
Closed with Code Change in Fabric OS v7.2.1e Defect ID: DEFECT000538092 Technical Severity: Medium Probability: Low Product: FOS Technology: Virtualization Reported In Release: FOS7.2.1 Technology Area: Access Gateway Symptom: Following a FOS firmware upgrade or hareboot, traffic to and from the Access Gateway stops after the N-Port trunk master is disabled. Condition: This issue will occur when the following conditions occur: - hareboot for any reason, including firmwaredownload.
Closed with Code Change in Fabric OS v7.2.1e Defect ID: DEFECT000540585 Technical Severity: High Probability: Medium Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.2.1 Technology Area: supportShow Symptom: Support Save output does not include VE or GE port information Condition: This is seen after multiple logical switches have been created and one or more of the logical switches have been deleted and the VE ports reside in a logical switch that was created after one that was deleted.
Closed with Code Change in Fabric OS v7.2.1e Defect ID: DEFECT000542995 Technical Severity: Medium Probability: Medium Product: FOS Technology: Virtualization Reported In Release: FOS7.2.1 Technology Area: Access Gateway Customer encounters a panic when enabling access gateway through webtools and then running Symptom: commands through the CLI subsequently. Condition: Enable AG mode in the switch through webtools. Recovery: Auto-recovery after panic dump.
Closed with Code Change in Fabric OS v7.2.1e Defect ID: DEFECT000547921 Technical Severity: High Probability: Low Product: FOS Technology: Virtualization Reported In Release: FOS7.3.1 Technology Area: Access Gateway Symptom: In an AG fabric or NPIV environment, device is not found or HBA detects SCSI command timeout and fabric switch stops routing AG switch/NPIV device traffic.
Closed with Code Change in Fabric OS v7.2.1d This sections lists the defects with Critical, High, and Medium Technical Severity closed with a code change as of November 20, 2014, in Fabric OS v7.2.1d. Defect ID: DEFECT000484537 Technical Severity: High Probability: Low Product: FOS Technology: System Reported In Release: FOS7.1.
Closed with Code Change in Fabric OS v7.2.1d Defect ID: DEFECT000516309 Technical Severity: High Probability: High Product: FOS Technology: Virtualization Reported In Release: FOS7.0.0_pha Technology Area: Access Gateway Symptom: Hosts have problems logging into the fabric through an Access Gateway. Condition: This may be encountered under the following conditions: - Hosts are connected to an Access Gateway. - F-ports on Access Gateway have NPIV logins.
Closed with Code Change in Fabric OS v7.2.1d Defect ID: DEFECT000523451 Technical Severity: High Probability: Medium Product: FOS Technology: Other Reported In Release: FOS7.2.
Closed with Code Change in Fabric OS v7.2.1d Defect ID: DEFECT000527848 Technical Severity: High Probability: Medium Product: FOS Technology: FICON Reported In Release: FOS7.2.0 Technology Area: FICON emulation Symptom: FCIP FICON emulated Tape VM SPOOL DUMP jobs fail after FOS upgrade Condition: This may be seen upon upgrade to FOS v7.2.
Closed with Code Change in Fabric OS v7.2.1d Defect ID: DEFECT000529761 Technical Severity: High Probability: Medium Product: FOS Technology: Security Reported In Release: FOS6.3.0 Technology Area: Security Vulnerability Symptom: Bash shell security vulnerabilities (CVE-2014-6271, CVE-2014-7169, CVE-2014-7186, CVE-20147187). These vulnerabilities allows certain malformed function definition to bypass privilege boundaries and execute unauthorized commands.
Closed with Code Change in Fabric OS v7.2.1d Defect ID: DEFECT000532888 Technical Severity: Medium Probability: Medium Product: FOS Technology: FICON Reported In Release: FOS7.1.0 Technology Area: FICON emulation Symptom: I/O Errors to FICON extended device over an FCIP Tunnel with FICON Emulation features enabled. Condition: When running FICON channel programs to an extended device that includes Repeat Execution CCW commands (typically used in Disk I/O channel programs).
Closed with Code Change in Fabric OS v7.2.1c This sections lists the defects with Critical, High, and Medium Technical Severity closed with a code change as of August 29, 2014, in Fabric OS v7.2.1c. Defect ID: DEFECT000490120 Technical Severity: Medium Probability: Low Product: FOS Technology: Monitoring/RAS Reported In Release: FOS6.4.3 Technology Area: Fabric Watch Fabric Watch may trigger false alarm message FW-1119 about fabric reconfiguration when no fabric Symptom: build really happened.
Closed with Code Change in Fabric OS v7.2.1c Defect ID: DEFECT000512057 Technical Severity: Medium Probability: High Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.2.0 Technology Area: Fabric Watch Symptom: Error messages start after firmware update from FOS v7.0.x to FOS v7.1.x and continue when upgrading to FOS v7.2.x. After downgrading back to 7.0.x, faulty port messages stop from Fabric Watch. Condition: Running FOS 7.
Closed with Code Change in Fabric OS v7.2.1c Defect ID: DEFECT000518620 Technical Severity: High Probability: Medium Product: FOS Technology: Other Reported In Release: FOS7.2.1 Technology Area: Other Symptom: Activation of the auto-tuning (serdestunemode --autoenable) on a switch that is also running MAPS could result in the MAPS daemon to restart. HA Sync will be temporarily lost during this time for each tuning value applied.
Closed with Code Change in Fabric OS v7.2.1b This sections lists the defects with Critical, High, and Medium Technical Severity closed with a code change as of July 15, 2014, in Fabric OS v7.2.1b. Defect ID: DEFECT000401075 Technical Severity: High Probability: Medium Product: FOS Technology: Security Reported In Release: FOS7.0.
Closed with Code Change in Fabric OS v7.2.1b Defect ID: DEFECT000467843 Technical Severity: Medium Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.0.2 Technology Area: End-to-end Performance Monitoring Symptom: The TX counter remains at "0x0000000100000000" after clears stats of EE performance monitors. Condition: No special condition is required: When EE monitor counters(TX/RX) are cleared on a port, 1 in top value of EE monitor counters(Tx/Rx) are not cleared.
Closed with Code Change in Fabric OS v7.2.1b Defect ID: DEFECT000473848 Technical Severity: High Probability: Low Product: FOS Technology: Management Reported In Release: FOS7.1.
Closed with Code Change in Fabric OS v7.2.1b Defect ID: DEFECT000482106 Technical Severity: Medium Probability: Medium Product: FOS Technology: FICON Reported In Release: FOS7.1.0 Technology Area: FICON CUP Symptom: Fbusy encountered when trying to bring up CUP connections following FCIP tunnel bounces. Condition: This may be seen only on FICON switches when attempting to bring up CUP connection after an FCIP tunnel is bounced.
Closed with Code Change in Fabric OS v7.2.1b Defect ID: DEFECT000485968 Technical Severity: Medium Probability: Medium Product: FOS Technology: Security Reported In Release: FOS7.1.1 Technology Area: Fabric Authentication Symptom: Unable to authenticate with TACACS server when setting up new Brocade switches. Condition: The issue will be hit if the TACACS+ Server Software converts the attribute to lower case and sends it to the switch.
Closed with Code Change in Fabric OS v7.2.1b Defect ID: DEFECT000490754 Technical Severity: High Probability: Medium Product: FOS Technology: Traffic Management Reported In Release: FOS7.0.2 Technology Area: BB Credits Symptom: Switch ports connected to storage controller become unresponsive. Condition: This rare condition may occur with Fabric Loop (FL) port after many resets. The port may get into "Port failed due to busy buffer stuck error" state.
Closed with Code Change in Fabric OS v7.2.1b Defect ID: DEFECT000492732 Technical Severity: Medium Probability: Medium Product: FOS Technology: Management Reported In Release: FOS6.4.3 Technology Area: Platform Services Symptom: After auto tuning FC8-64 in DCX-4s, the blade may be faulted. Condition: When auto-tuning is run on FC8-64 blade in a DCX-4s, some values attempted can cause this blade or peer core blade to fault. .
Closed with Code Change in Fabric OS v7.2.1b Defect ID: DEFECT000496527 Technical Severity: High Probability: High Product: FOS Technology: Distance Reported In Release: FOS7.2.0 Technology Area: FCIP Symptom: Unable to run traffic on low bandwidth FCIP tunnel. Customer sees application suspends. Condition: This may be encountered on low bandwidth FCIP tunnels Workaround: If possible, increase the FCIP Circuit minimum data rate.
Closed with Code Change in Fabric OS v7.2.1b Defect ID: DEFECT000500532 Technical Severity: High Probability: High Product: FOS Technology: Other Reported In Release: FOS7.2.0 Technology Area: Other Symptom: On BR6547, Firmware status is shown incorrectly in firmwareImageinfo object. Condition: FirmwareStatus is shown as "inACtive", even though firmware is active. Defect ID: DEFECT000500759 Technical Severity: Medium Probability: High Product: FOS Technology: Other Reported In Release: FOS7.2.
Closed with Code Change in Fabric OS v7.2.1b Defect ID: DEFECT000503299 Technical Severity: High Probability: Low Product: FOS Technology: Other Reported In Release: FOS6.4.
Closed with Code Change in Fabric OS v7.2.1b Defect ID: DEFECT000513923 Technical Severity: High Probability: High Product: FOS Technology: Virtualization Reported In Release: FOS7.2.0 Technology Area: Access Gateway Symptom: ELS commands get rejected and host on AG switch can no longer communicate with the target in the 3rd party vendor fabric.
Closed with Code Change in Fabric OS v7.2.1a This sections lists the defects with Critical, High, and Medium Technical Severity closed with a code change as of March 7th, 2014, in Fabric OS v7.2.1a. Defect ID: DEFECT000461189 Technical Severity: High Probability: Low Product: FOS Technology: Management Reported In Release: FOS7.2.0 Technology Area: Web Tools FOS7.2.
Closed with Code Change in Fabric OS v7.2.1a Defect ID: DEFECT000475264 Technical Severity: High Probability: Medium Product: FOS Technology: Security Reported In Release: FOS7.1.1 Technology Area: Fabric Authentication FOS7.2.1a(Fixed) Closed In Release(s): Symptom: After password expiration in switches with multiple logical switches, excessive login failures may trigger repeated secd panics.
Closed with Code Change in Fabric OS v7.2.1a Defect ID: DEFECT000484327 Technical Severity: High Probability: Low Product: FOS Technology: Traffic Management Reported In Release: FOS7.1.0 Technology Area: FC-FC routing FOS7.2.
Closed with Code Change in Fabric OS v7.2.1a Defect ID: DEFECT000488202 Technical Severity: High Probability: Medium Product: FOS Technology: Distance Reported In Release: FOS7.1.0 Technology Area: IPsec FOS7.2.1a(Fixed) Closed In Release(s): Symptom: FCIP Circuit bounces due to replay checks when running IPSec with unidirectional traffic from the lower order IP address to the higher IP address on the circuit.
Closed with Code Change in Fabric OS v7.2.1a Defect ID: DEFECT000491192 Technical Severity: Critical Probability: Medium Product: FOS Technology: Traffic Management Reported In Release: FOS7.2.0 Technology Area: Routing FOS7.2.1a(Fixed) Closed In Release(s): Symptom: FOSv7.2.0, 7.2.0a, 7.2.0b, 7.2.0c, 7.2.1 with user defined logical switch, hosts may be unable to reach targets due to frames being corrupted or traffic flow may appear to stop.
Closed with Code Change in Fabric OS v7.2.1a Defect ID: DEFECT000494570 Technical Severity: High Probability: High Product: FOS Technology: Management Reported In Release: FOS7.2.0 Technology Area: Firmware upload/download FOS7.2.1a(Fixed) Closed In Release(s): Symptom: Upgrading to FOS7.2.0c (which contains a fix for defect 491192) with pre-existing user-defined logical switches may lead to fabric wide performance issue or hosts not being able to see targets after a slot offline event .
Closed with Code Change in Fabric OS v7.2.1 This sections lists the defects with Critical, High, and Medium Technical Severity closed with a code change as of December 13, 2013 in Fabric OS v7.2.1. Note: Note these defects are formatted with an updated defect table structure applying to all new or previously unpublished defects. Defect ID: DEFECT000415126 Technical Severity: High Probability: High Product: FOS Technology: Management Reported In Release: FOS7.1.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000455170 Technical Severity: Medium Probability: Low Product: FOS Technology: Management Reported In Release: FOS7.1.0 Technology Area: CLI FOS7.2.1(Fixed) Closed In Release(s): Symptom: On a switch without license, while changing the date using "date" command will display: "No licenses installed." Even though date properly updated by the command.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000463819 Technical Severity: High Probability: Low Product: FOS Technology: Traffic Management Reported In Release: FOS7.0.2 Technology Area: FC-FC routing Closed In Release(s): FOS7.2.1(Fixed) Symptom: Class 2 GPN_FT queries may fail with excessive targets (127 targets) in the fabric.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000467051 Technical Severity: Medium Probability: High Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.0.2 Technology Area: Fabric Watch FOS7.2.1(Fixed) Closed In Release(s): Symptom: switchstatuspolicy shows incorrect port count which may impact the accuracy of switch status Condition: switchstatuspolicy incorrectly accounts for logical ports into the total physical port count.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000469507 Technical Severity: High Probability: Low Product: FOS Technology: Security Reported In Release: FOS7.0.1 Technology Area: Encryption FOS7.2.1(Fixed) Closed In Release(s): Symptom: Tape backup jobs on encrypted tape may fail. Condition: Issue will be seen on Brocade Encryption Switch or FS8-18 blade with hosts and targets that doesn’t support SRR/FCP_CONF and tape pipelining is enabled for the tape LUN.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000474392 Technical Severity: Medium Probability: Low Product: FOS Technology: Security Reported In Release: FOS7.1.0 Technology Area: Encryption FOS7.2.1(Fixed) Closed In Release(s): Symptom: In a BES environment with CTC, hosts may lose access to LUNs temporarily. Condition: Issue will be seen on Brocade Encryption Switch or FS8-18 blade when BES/FS8-18 acting as an N port device, aborted the PLOGI in advance.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000476595 Technical Severity: High Probability: Low Product: FOS Technology: Security Reported In Release: FOS7.0.2 Technology Area: Encryption FOS7.2.1(Fixed) Closed In Release(s): Symptom: In a heavy I/O environment, tape mounts are rejected for LTO drives on encryption blade.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000477917 Technical Severity: High Probability: Medium Product: FOS Technology: Traffic Management Reported In Release: FOS6.4.3 Technology Area: Routing Closed In Release(s): FOS7.2.1(Fixed) Symptom: Spinfab fails across TI Zone when link cost is higher than that of normal E-ports. Condition: Testing ports bounced after link cost was changed to a higher than normal traffic E-ports between the same two domains.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000481291 Technical Severity: Medium Probability: Low Product: FOS Technology: Security Reported In Release: FOS7.0.2 Technology Area: Encryption FOS7.2.1(Fixed) Closed In Release(s): Symptom: After HAfailover of Group leader, member node is deleted from Encryption Group.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000423640 Technical Severity: High Summary: Upgrade the flash card driver to a newer version. Symptom: On rare occasions excessive writing to an old flash card may cause it to no longer be accessible during switch bootup. Risk of Fix: Low Probability: Low Embedded Platform Services Feature: Function: Other Reported In Release: FOS6.4.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000453711 Technical Severity: Medium Summary: Certificate key is not deleted when the certificate is deleted from Non-Default switch using seccertutil command. Symptom: Standby CP/switch may continuously reboot with error message such as "SSLCertificateFile: file ‘/etc/fabos/certs/sw0/xxx.crt’ does not exist or is empty on console".
Closed with Code Change in Fabric OS v7.2.1 Technical Severity: Medium Defect ID: DEFECT000465730 Summary: Update asic parity error monitoring threshold and behavior. Symptom: Default threshold for low level Asic parity error will fault blade with a few error. New CLI options to "chassiscfgperrthr" will allow customers to adjust the values based on their environments. Risk of Fix: Low Probability: Low Feature: FOS Software Function: ASIC Driver Reported In Release: FOS7.1.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000467681 Technical Severity: High Summary: Blade server shows incorrect firmware version in IOM module after a switch hotplug Symptom: Blade server still displays older Firmware Version in IOM module after upgrade and shows none after switch hotplug Risk of Fix: Low Probability: High Embedded Platform Services Feature: Function: Other Reported In Release: FOS7.2.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000468455 Technical Severity: High Summary: QoS allowed ASIC buffer pool to become over allocated Symptom: Portbuffershow indicated a negative value in the remaining buffers after QoS was enabled on an extended distance link Risk of Fix: Low Probability: Medium 8G ASIC Driver Feature: Function: ASIC Driver Reported In Release: FOS7.2.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000470487 Technical Severity: Medium Summary: Fabric watch not calculating VEX port packet loss correctly. Symptom: Erroneous FW-1190 error messages seen on different VEX tunnels: Event: , VEXport#3/16,Packet Loss, is above high boundary(High=100, Low=0). Current value is 1176 Percentage(%). Severity: Warning Risk of Fix: High Probability: Medium Feature: FABRIC WATCH Function: Other Reported In Release: FOS7.2.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000472563 Technical Severity: Medium Summary: GA_NXT is rejected causing path loss Symptom: After rebooting a host, a subsequent GA_NXT is performed by that is rejected by the switch causing path fail for host storage. Risk of Fix: Low Probability: Low FOS Software Feature: Function: Fabric Services Reported In Release: FOS6.4.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000473548 Technical Severity: High Summary: When flows are monitored in MAPS, switch disable/enable or port enable/disable could trigger unexpected MAPS RASLOGs Symptom: Unexpected MAPS RASLOGs with large values are triggered for the flows affected by port enable/disable or switch enable/disable operations. Risk of Fix: Low Probability: High Feature: Advanced Monitoring Services Function: Flows Reported In Release: FOS7.2.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000475320 Technical Severity: Medium Summary: Reset doesn't work for flow mirror feature when wrap is disabled Symptom: Unable to reset a flow mirror when wrap is disabled. Risk of Fix: Low Probability: Medium Feature: Network Patroller Function: Flow Mirroring Reported In Release: FOS7.2.