Typical Power Supply Requirements Guidelines for Blades in DCX 8510-8
(For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications
in the 8510-8 Backbone Hardware Reference Manual)
Configured
Number of Ports
Blades
Type of Blade
DCX 8510-8
@110 VAC
(Redundant
configurations)
DCX 8510-8
@200-240
VAC (Redundant
configurations)
Comments
384 16Gb ports +
QSFP ICLs
FC16-48
Port Blade
Not Supported
4 Power
Supplies
200-240VAC:
For DCX 8510-8, four
(2+2)
1
220V AC Power
Supplies are required
384 16Gb ports +
QSFP ICLs
FC16-64
Port Blade
4 Power Supplies
2 Power
Supplies
200-240VAC: 1+1
Power Supplies
110VAC: 2+2
1
Power Supplies
384 8Gb ports +
QSFP ICLs
FC8-48E
Port Blade
4 Power Supplies
4 Power
Supplies
200-240VAC:
For DCX 8510-8, four
(2+2)
1
220V AC Power
Supplies are required
Any combination
of 8Gb or 16Gb
ports and
intelligent blades
with QSFP ICLs
FC16-32, FC16-48,
FC8-64, FC8-32E,
FC8-48E, FS8-18,
FX8-24
Intelligent
Blade
/Combination
Dependent on
configuration.
Requires power
calculation for
specific
configuration
2 or 4 Power
Supplies,
depending on
configuration
For DCX 8510-8, four
(2+2)
1
220V AC Power
Supplies are required
when any special
purpose blade are
installed
512 16Gb ports
FC16-64
Port Blade
4 Power Supplies
2 Power
Supplies
200-240VAC: 1+1
Power Supplies
110VAC: 2+2
1
Power Supplies
512 16Gb ports +
QSFP ICLs
FC16-64
Port Blade
4 Power Supplies
2 Power
Supplies
200-240VAC: 1+1
Power Supplies
110VAC: 2+2
1
Power Supplies
Table 4 Power Supply Requirements for DCX 8510-8
Notes:
1. When 2+2 power supply combination is used, the users are advised to configure the Fabric Watch setting for
switch marginal state to be two power supplies. Users can use the CLI switchstatuspolicyset to configure this
value if the current value is set to zero. In FOS v7.0.x, the default setting for the marginal state due to missing
power supplies is incorrectly set to zero, which will prevent Fabric Watch from generating notifications when the
switch enters the marginal state due to missing power supplies