Deployment Guide

902 Fabric OS Command Reference
53-1003131-01
portShow
2
Compression: On (Aggressive)
Fastwrite: Off
Tape Acceleration: Off
TPerf Option: Off
IPSec: Disabled
QoS Percentages: High 50%, Med 30%, Low 20%
Remote WWN: Not Configured
Local WWN: 10:00:00:05:1e:a5:54:bd
Peer WWN: 00:00:00:00:00:00:00:00
Circuit Count: 4
Flags: 0x00000000
FICON: On
FICON XRC: Off
FICON Tape Write: On
FICON Tape Read: On
FICON TinTir Emul: On
FICON Dvc Acking: On
FICON Read BLK-ID: On
FICON Teradata Write: On
FICON Teradata Read: On
Tape Write Pipe: 63
Tape Read Pipe: 65
Tape Write Devs: 32
Tape Read Devs: 32
Tape Write Timer: 300
Tape Max Chain: 3200000
FICON OXID Base: 0x8000
FICON Debug Flags: 0xf7c90000
To display an FCIP tunnel with FICON disabled:
switch:admin> portshow fciptunnel 16
-------------------------------------------
Tunnel ID: 16
Tunnel Description:
Admin Status: Enabled
Oper Status: Up
Compression: On (Aggressive)
Fastwrite: Off
Tape Acceleration: Off
TPerf Option: Off
IPSec: Disabled
QoS Percentages: High 50%, Med 30%, Low 20%
Remote WWN: Not Configured
Local WWN: 10:00:00:05:1e:a5:54:bd
Peer WWN: 00:00:00:00:00:00:00:00
Circuit Count: 4
Flags: 0x00000000
FICON: Off
To display an FCIP tunnel with additional circuit information:
switch:admin> portshow fciptunnel 1/12 -c
Tunnel ID: 1/12
Tunnel Description:
Admin Status: Enabled
Oper Status: Up
Compression: Off
Fastwrite: Off
Tape Acceleration: Off