BL-1012
Message bport <port number> port int. is disabled. status=0x<interrupt status> Port <port
number> will be re-enabled in 1 minute.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the port generated an excessive number of interrupts that may prove unrecoverable to the
switch operation. The port is disabled to prevent the control processor (CP) from becoming too busy. The
bport is the blade port; this number may not correspond to a user port number.
Recommended
Action
Make sure to capture the console output during this process.
Check for a faulty cable, small form-factor pluggable (SFP) transceiver, or device attached to the
specified port.
On a bladed switch, run the slotPowerOff and slotPowerOn commands to power cycle the blade.
On a non-bladed switch, reboot or power cycle the switch.
If the message persists, replace the blade or the (non-bladed) switch.
BL-1013
Message bport <port number> port is faulted. status=0x<interrupt status> Port <port
number> will be re-enabled in 1 minute.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the port generated an excessive number of interrupts that may prove fatal to the switch
operation. The port is disabled to prevent the control processor (CP) from becoming too busy. The bport
number displayed in the message is the blade port; this number may not correspond to a user port
number.
Recommended
Action
Make sure to capture the console output during this process.
Check for a faulty cable, small form-factor pluggable (SFP) transceiver, or device attached to the
specified port.
On a bladed switch, run the slotPowerOff and slotPowerOn commands to power cycle the blade.
On a non-bladed switch, reboot or power cycle the switch.