Developers Guide

186 Fabric OS Message Reference
53-1003140-01
BL-1025
5
BL-1025
Message All GigE/FCIP/Virtualization/FC Fastwrite ports on the blade in slot <slot number>
will be reset as part of the firmware upgrade.
Message Type LOG
Severity INFO
Probable Cause Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the
cold upgrade. As part of the upgrade, all the Gigabit Ethernet, Fibre Channel over IP (FCIP),
virtualization data elements, and FC Fastwrite ports were reset.
Recommended
Action
No action is required.
BL-1026
Message Internal port offline during warm recovery, state <port state> (0x<port ID>).
Message Type LOG
Severity CRITICAL
Probable Cause Indicates that an internal port went offline during warm recovery of the switch. The switch will reboot and
start cold recovery.
Recommended
Action
Execute the supportSave command and then reboot switch. If the problem persists, replace the switch.
BL-1027
Message Blade in slot <slot number> faulted, boot failed; status 0x<boot status> 0x<1250 0
boot status> 0x<1250 1 boot status>.
Message Type LOG
Severity CRITICAL
Probable Cause Indicates that the blade failed to boot properly.
Recommended
Action
Reboot or power cycle the blade using the slotPowerOff and slotPowerOn commands.
If the message persists, replace the blade.