Developers Guide

196 Fabric OS Message Reference
53-1003140-01
BLS-1003
5
BLS-1003
Message An IPsec/IKE policy was deleted.
Message Type AUDIT | LOG
Class CFG
Severity INFO
Probable Cause Indicates that an Internet Protocol Security (IPsec) or Internet Key Exchange (IKE) policy was deleted
and the configuration file was updated.
Recommended
Action
No action is required.
BLS-1004
Message Tape Read Pipelining is being disabled slot (<slot number>) port (<user port
index>) tunnel (<The configured tunnel ID (0-7)>).
Message Type LOG
Severity INFO
Probable Cause Indicates that the Fabric OS version on the remote end of the tunnel does not support Tape Read
Pipelining.
Recommended
Action
No action is required.
BLS-1005
Message S<slot number>,P<user port index>(<blade index>) [OID 0x<port OID>]: <string name
of ge>: port faulted due to SFP validation failure. Please check if the SFP is
valid for the configuration.
Message Type LOG
Severity ERROR
Probable Cause Indicates a deteriorated small form-factor pluggable (SFP) transceiver, an incompatible SFP transceiver
pair, or a faulty cable between the peer ports.
Recommended
Action
Verify that compatible SFP transceivers are used on the peer ports, the SFP transceivers have not
deteriorated, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable if
necessary.