PLAT-1006
5
PLAT-1006
Message Unknown midplane revision.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the chassis has a midplane whose revision is unknown.
This message occurs only on the Brocade M6505.
Recommended
Action
Install newer firmware in the Chassis Management Controller (CMC).
PLAT-1007
Message BladeSystem Chassis type is unknown, setting maximum internal port speed to 8Gbps.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the Onboard Administrator (OA) could be running an old version of firmware.
If OA firmware is new enough to support Enclosure Information, then OA failed to send the Enclosure
Information soon enough to allow the internal ports to run at 16 GFC.
This message occurs only on the Brocade 6548.
Recommended
Action
No action is required.
PLAT-1008
Message BladeSystem Enclosure Information arrived late from OA.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the Onboard Administrator (OA) failed to send the Enclosure Information soon enough to
allow the internal ports to run at 16 GFC.
This message occurs only on the Brocade 6548.
Recommended
Action
Execute the hareboot command, followed by the portdisable and portenable commands to allow
internal ports to run at 16 GFC.