Developers Guide

Fabric OS Message Reference 793
53-1003140-01
SEC-1183
5
Recommended
Action
No action is required.
SEC-1183
Message Policy to binary conversion error: Port <port number> is out range.
Message Type LOG
Severity ERROR
Probable Cause Indicates a security database conversion has failed because of an invalid value.
Recommended
Action
Retry the command with a valid value.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
SEC-1184
Message <Security server (RADIUS/LDAP/TACACS+)> configuration change, action <action>,
server ID <server name>.
Message Type LOG
Severity INFO
Probable Cause Indicates the specified action is applied to the specified remote authentication dial-in user service
(RADIUS/LDAP/TACACS+) server configuration. The possible actions are ADD, REMOVE, CHANGE,
and MOVE.
Recommended
Action
No action is required.
SEC-1185
Message <action> switch DB.
Message Type LOG
Severity INFO
Probable Cause Indicates the switch database was enabled or disabled as the secondary authentication, authorization,
and accounting (AAA) mechanism when remote authentication dial-in user service
(RADIUS/LDAP/TACACS+) is the primary AAA mechanism.
Recommended
Action
No action is required.