Developers Guide

Fabric OS Message Reference 963
53-1003140-01
ZEUS-1016
5
ZEUS-1016
Message Port is faulted due to port re-initialization failure on internal Port S<slot
number>,P<port number>(<blade port number>) with reason <port fault reason>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the specified port failed due to port re-initialization failure.
Recommended
Action
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.
ZEUS-1028
Message Detected excessive Link resets on the port in a second. Slot <slot number>, Port
<port number>(<blade port number>).
Message Type LOG
Severity WARNING
Probable Cause Indicates that the port received excessive link resets from peer port within 1 second and that exceeded
threshold.
Recommended
Action
When this error is observed persistently, change the small form-factor pluggable (SFP) transceiver or
cable on the peer port to which this port is connected.