Messages Reference Guide

Fabric OS Message Reference 127
53-1002749-01
AG-1018
5
AG-1018
Message Host port should not be connected to port <port number> which is configured as
N_Port.
Message Type LOG
Severity ERROR
Probable Cause Indicates that an initiator or target port is erroneously connected to a port configured for N_Port
operation.
Recommended
Action
Execute the switchShow command to display the status of all ports in the system. Execute the
portCfgShow command to display the list of ports currently configured as N_Ports. Make sure the host
is connected to an F_port.
AG-1019
Message Unable to failover N_Port <port number>. No other N_Port in port group:<pgid> is
online.
Message Type LOG
Severity WARNING
Probable Cause Indicates that failover across port groups is not supported.
Recommended
Action
Check whether an alternate N_Port is configured in the specified port group using the ag --pgshow
command.
AG-1020
Message F_Ports to N_Ports route/mapping has been changed.
Message Type LOG
Severity INFO
Probable Cause Indicates that F_Port-to-N_Port mapping has been changed because the switch has come online or
some new N_Ports or F_Ports have come online.
Recommended
Action
Execute the ag --mapshow command to display the updated F_Port-to-N_Port mapping.