Messages Reference Guide

Fabric OS Message Reference 283
53-1002749-01
EM-1017
5
EM-1017
Message Uncommitted WWN change detected. Cold reboot required.
Message Type LOG
Severity WARNING
Probable Cause Indicates that a user did not commit a changed World Wide Name (WWN) value before performing a
system restart, power cycle, or firmware download operation.
Recommended
Action
Change and commit the new WWN value.
EM-1018
Message CP blade in slot <slot number> failed to retrieve current chassis type (<return
code>/<error code>/0x<unit number>).
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that there was a failure to read the chassis type from the system.
Recommended
Action
Verify that the control processor (CP) blade is operational and is properly seated in its slot.
EM-1019
Message Current chassis configuration option (<Chassis config option currently in effect>)
is not compatible with standby firmware version (Pre 4.4), cannot allow HA Sync.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the current chassis configuration option is not supported by the firmware on the standby
control processor (CP). This is true even if the standby CP comes up and is operational. High availability
(HA) synchronization of the CPs will not be allowed.
Recommended
Action
Change the chassis configuration option to 1 using the chassisConfig command, or upgrade the
firmware on the standby CP to the version running on the active CP.