Messages Reference Guide

Fabric OS Message Reference 287
53-1002749-01
EM-1037
5
EM-1037
Message <FRU Id> is no longer faulted.
Message Type LOG
Severity INFO
Probable Cause Indicates that the specified power supply is no longer marked faulty; probably because its AC power
supply has been turned on.
Recommended
Action
No action is required.
EM-1042
Message Important FRU header data for <FRU Id> is not valid.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the specified field-replaceable unit (FRU) has an incorrect number of sensors in its FRU
header-derived information. This could mean that the FRU header was corrupted or read incorrectly, or
corrupted in the object database, which contains information about all FRUs.
Recommended
Action
Reseat the FRU. If the problem persists, replace the FRU.
EM-1043
Message Can't power <FRU Id> <state (on or off)>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the specified field-replaceable unit (FRU) cannot be powered on or off.
Recommended
Action
The specified FRU is not responding to the commands and should be replaced.