Messages Reference Guide

Fabric OS Message Reference 373
53-1002749-01
FCR-1097
5
FCR-1097
Message Failed to get <data type> for <message phase> message: port <port number>, retval
<error code>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the authentication process failed to get a particular authentication value at certain phase.
Data type is the payload or structure that failed to get memory.
Recommended
Action
Usually this problem is transient. The authentication may fail.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers;
then run the supportSave command and contact your switch service provider.
FCR-1098
Message Invalid message code for <message phase> message: port <port number>.
Message Type LOG
Severity ERROR
Probable Cause Indicates the receiving payload does not have valid message code for a particular authentication phase.
Recommended
Action
Usually this problem is transient. The authentication may fail.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers;
then run the supportSave command and contact your switch service provider.