Messages Reference Guide

Fabric OS Message Reference 631
53-1002749-01
NS-1007
5
Recommended
Action
The switch will process the new process ID (PID) and leave the existing PID intact. Subsequent switch
operations will clean up the obsolete PID. However, it is recommended that administrators remove
devices with a duplicate WWN.
NS-1007
Message NS has detected a logical ISL port <LISL port number> in TI zone <TI zone name> in
fabric <Fabric ID>. Routing may not be setup correctly.
Message Type LOG
Severity WARNING
Probable Cause Indicates that a logical inter-switch link (LISL) is detected in a traffic isolation (TI) zone.
Recommended
Action
Remove the LISL port from the TI zone because the routing may not be set up correctly.
NS-1008
Message Open FR license not installed.
Message Type LOG
Severity WARNING
Probable Cause Indicates that Open FR license is not installed and therefore local devices involved in Open FR will not
function.
Recommended
Action
Install the Open FR license or relocate Open FR devices to a licensed switch.
NS-1009
Message NS has detected a device with Node WWN as zero, pid 0x<device PID>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that a device has logged in with node World Wide Node Name (WWNN) as zero. Brocade
Network Advisor (BNA) will not show the port connectivity.
Recommended
Action
Check the device that logged in. The device could be faulty.