Messages Reference Guide

852 Fabric OS Message Reference
53-1002749-01
SYSC-1001
5
SYSC Messages
SYSC-1001
Message Failed to run <Name of program that could not be run (string)>:<System internal
error message (string)>.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that one of the programs would not run on the system during the boot sequence.
Recommended
Action
If the message is reported during a reboot after new firmware has been loaded, try reloading the
firmware using the firmwareDownload command.
If the message persists, there may be a conflict between the two versions of firmware or the nonvolatile
storage may be corrupted.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
SYSC-1002
Message Switch bring-up timed out.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the system timed out during a reboot or failover sequence, waiting for one or more
programs to register with system services or to fail over to active status.
Recommended
Action
The switch is in an inconsistent state and can be corrected only by a reboot or power cycle. Before
rebooting the chassis, record the firmware version on the switch or control processor (CP) and run the
haDump command. If this is a dual-CP switch, gather the output from the CP in which this log message
appeared.
SYSC-1004
Message Daemon <Daemon name to restart> restart successful.
Message Type LOG
Severity INFO
Probable Cause Indicates that a terminated daemon is restarted by the system automatically.
Recommended
Action
Execute the supportSave command to gather troubleshooting data. No further action is required.