Messages Reference Guide

866 Fabric OS Message Reference
53-1002749-01
TS-1006
5
TS-1006
Message <message>.
Message Type LOG
Severity INFO
Probable Cause Indicates that a time service event is occurring or has failed. The message can be one of the following:
Init failed. Time Service exiting - Initialization error, but the time server exits.
Synchronizing time of day clock - Usually logged during temporary operational issues when the
clock goes out of synchronization. For example, when a time update packet is missed due to
fabric reconfiguration or role change of the principal or primary fabric configuration server
(FCS) switch. If the message does not recur, it can be ignored.
Validating time update - Usually logged during temporary operational issues when a time
update packet cannot be validated in a secure fabric. For example, during fabric
reconfiguration or role change of the primary FCS switch. If the message does not recur, it can
be ignored.
Recommended
Action
No action is required.
TS-1007
Message <message>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that a switch is trying to set the clock server, which is not the primary fabric configuration server
(FCS) across the fabric. A consistent FCS policy must be implemented across the fabric.
Recommended
Action
Execute the secPolicyShow command to verify that the FCS policy is consistent across the fabric.
TS-1008
Message <New clock server used> Clock Server used instead of <Old server configured>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the source of fabric time synchronization distributed from the principal or primary fabric
configuration server (FCS) switch was changed to another configured clock server. This happens when
the Network Time Protocol (NTP) query to the current active external clock server failed.