XTUN-2004
5
Recommended
Action
If the tunnel or circuit has not been administratively disabled or deleted, a possible network error or
disruption has occurred.
XTUN-2004
Message FCIP Tunnel <VE Port (Tunnel) Number> <Priority Class>-Pri QoS UP.
Message Type LOG
Severity INFO
Probable Cause Indicates that the specified quality of service (QoS) for this tunnel is up. This applies to the data classes
only. When the F-Class comes online, the tunnel itself is marked as up.
Recommended
Action
No action is required.
XTUN-2005
Message FCIP Tunnel <VE Port (Tunnel) Number> <Priority Class>-Pri QoS DOWN (<Reason>).
Message Type LOG
Severity ERROR
Probable Cause Indicates that the specified quality of service (QoS) for this tunnel has gone down. This applies to the
data classes only. If the F-Class goes down, the tunnel itself is marked as down.
Recommended
Action
If tunnel or circuit has not been administratively disabled or deleted, a possible network error or
disruption has occurred.
XTUN-2006
Message FCIP Tunnel <VE Port (Tunnel) Number> CREATED (<Originator>).
Message Type LOG
Severity INFO
Probable Cause Indicates that the specified tunnel has been successfully created.
Recommended
Action
No action is required.