MIB Reference Guide

Fabric OS MIB Reference 137
53-1002750-01
sw traps
6
TABLE 44
Trap name and OID Variables Description
swFault
1.3.6.1.4.1.1588.2.1.1.1
.0.1
swDiagResult
swSsn
This trap is no longer generated.
A swFault is generated whenever the diagnostics
detect a fault with the switch.
#TYPE Switch is faulty.
#SUMMARY Faulty reason: %d and SSN is #%s
#ARGUMENTS 0, 1
#SEVERITY Critical
#TIMEINDEX 1
#STATE Nonoperational
swSensorScn
1.3.6.1.4.1.1588.2.1.1.1
.0.2
swSensorStatus
swSensorIndex
swSensorType
swSensorValue
swSensorInfo
swSsn
This object is obsoleted by swFabricWatchTrap.
A swSensorScn (2) is generated whenever an
environment sensor changes its operational state:
for instance, if a fan stop working. The VarBind in the
Trap Data Unit contain the corresponding instance of
the sensor status, sensor index, sensor type, sensor
value (reading), and sensor information. Note that
the sensor information contains the type of sensor
and its number, in textual format.
#TYPE A sensor (temperature, fan, or other)
changed its operational state.
#SUMMARY %s: is currently in state %d and SSN is
#%s
#ARGUMENTS 4, 0, 5
#SEVERITY Informational
#TIMEINDEX 1
#STATE Operational
swFCPortScn
1.3.6.1.4.1.1588.2.1.1.1
.0.3
swFCPortOpStatus
swFCPortIndex
swFCPortName
swFCPortWwn
swFCPortPrevType
swFCPortBrcdType
swSsn
swFCPortFlag
swVfId
A swFCPortScn (3) is generated whenever an FC port
changes its operational state or port type. The events
that trigger this trap are as follows:
Port changes its state to online or offline.
Port type changes to E_port, F_port, or FL_port.
The VarBind in the Trap Data Unit contains the
corresponding instance of the FC port's operational
status, index, swFCPortName, and swSsn.
swFCPortName and swSsn are optional.
#TYPE A Fibre Channel Port changed its
operational state.
#SUMMARY Port Index %d changed state to %d.
Port Name: %s and SSN is #%s
#ARGUMENTS 1, 0, 2, 3
#SEVERITY Informational
#TIMEINDEX 1
#STATE Operational