1. Configure the Brocade switch into dynamic D_Port mode as follows.
a) Disable the switch by entering the switchDisable command.
NOTE
Dynamic D_Port is enabled by default.
switch:admn> switchdisable
b) Enter the configure command, and then select "D-Port Parameters" and ensure that dynamic D_port testing is enabled and
on-demand port testing is disabled.
Configure...
Fabric parameters (yes, y, no, n): [no]
Virtual Channel parameters (yes, y, no, n): [no]
F-Port login parameters (yes, y, no, n): [no]
D-Port Parameters (yes, y, no, n): [no] y
Dynamic D-Port (on, off): on
On Demand D-Port (on, off): off
2. Re-enable the switch by using the switchEnable command.
switch:admin> switchenable
3. From the host server, start D_Port testing by selecting the Emulex "OneCommand Manager."
4. For each port under test, click the Diagnostics tab, then click D_Port Tests.
Enabling D_Port testing with a QLogic HBA
This task illustrates how to enable D_Port testing with a QLogic HBA.
D_Port testing is supported on QLogic 16G and 32G cards. For the latest firmware/driver and product-specific details, go to
www.qlogic.com. If the latest firmware/driver supporting D_Port testing is installed in the server, nothing further needs to be done on the
server side.
NOTE
The QLogic cards support only electrical and optical loopback tests. They do not support link traffic tests.
1. On the Brocade switch, convert the port from an F_Port to a D_Port, disabling the specified F_Port by entering the portDisable
port_ID
command, as in the following example.
switch:admin> portdisable 1/1
2. Enter the portCfgDport --enable
port_ID
command.
switch:admin> portcfgdpdort --enable 1/1
3. Enable the port by using the portEnable
port_ID
command.
switch:admin> portenable 1/1
The D_Port test begins automatically.
BCU D_Port commands
The following BCU commands can be used for D_Port configuration and control:
Diagnostic Port
Brocade Fabric OS Administration Guide, 8.0.1