TABLE 88 External port to slotShow port mapping for core blades
External port number slotShow FC port numbers External port number slotShow FC port numbers
0 0-3 8 32-35
1 4-7 9 36-39
2 8-11 10 40-43
3 12-15 11 44-47
4 16-19 12 48-51
5 20-23 13 52-55
6 24-27 14 56-59
7 28-31 15 60-63
Following are ICL configuration guidelines for trunking bandwidth and High Availability:
A minimum of four ICL ports (two on each core blade) must be connected between each chassis pair.
The dual connections on each core blade must reside within the same ICL trunk boundary on the core blades.
If more than four ICL connections are required between a pair of X6 chassis, additional ICL connections should be added in
pairs, one on each core blade with each additional pair residing within the same trunk boundary
For High Availability, you should have at least two ICLs from each core blade. The following illustration shows two X6-8 chassis
connected with full redundancy using four ICL connections.