Reference Guide

--------------------------------------------------------------------------------
1 : 350 --> 12 10:00:08:00:88:04:93:94 39 fcr_sw 4G 8G TRUNK
Configuring EX_Ports on an ICL
The following restrictions apply when configuring EX_Ports on an ICL:
Both the active and standby CP must be running Fabric OS 7.2.0 or later in the case of DCX 8510 Backbone.
EX_Port on ICL is supported in DCX 8510 Backbones and X6 Directors when all the port blades in the chassis belong to one of
these blade types: FC16-32, FC16-48, FC16-64, FC32-48.
NOTE
Device discovery will not occur properly with ICL EX_Port connected edge fabrics if the FC router has unsupported
blades that are not mentioned in the previous restriction.
Switches must have Virtual Fabrics enabled.
EX_Ports on ICLs are allowed only on the base switch. F_Ports are not supported in the base switch.
You must be in Brocade native mode.
You cannot configure a VEX_Port on an ICL .
The ICLs must be in a symmetric topology. For more information on topologies, refer to the chapter on Inter-Chassis Links
(ICLs).
Bladeless configuration (where the chassis has core blades but no application blades) is not supported.
To configure EX_Ports on an ICL, perform the following steps:
1. Configure an 8-bit zero-based Dynamic Area mode or a 10-bit Dynamic Area mode on the FC router to bring up ICL
EX_Ports.
Configure...
Enable a 256 Area Limit
(0 = No,
1 = Zero Based Area Assignment,
2 = Port Based Area Assignment): (0..2) [0]
The following options are available:
0: 10-bit Dynamic Area Mode. ICL EX_Ports, F_Ports, and regular EX_Ports have 8-bit areas.
1: 8-bit Dynamic Area Mode. ICL_EX ports have 8-bit areas.
2: Not permitted if ICL ports are present in the logical switch.
2. On the FC router, disable all QSFP ports by issuing the portDisable command.
switch:admin> portdisable 6/20-23
You can verify that all ports have been disabled by issuing the portShow command for the ports.
3. Configure EX_Ports on the ICL by issuing the portCfgEXPort command. If you configure EX_Port on one of the QSFP ports,
the configuration is automatically propagated to the other 3 QSFP ports.
The following example configures EX_Port on one of the QSFP ports.
switch:admin> portcfgexport 6/20 -a 1 -f 45
2013/04/25-21:21:54, [FCR-1071], 29805, SLOT 4 | FID 2, INFO, Pluto, Port 6/20 is changed from non
FCR port to FCR port.
2013/04/25-21:21:54, [FCR-1071], 29806, SLOT 4 | FID 2, INFO, Pluto, Port 6/21 is changed from non
FCR port to FCR port.
2013/04/25-21:21:55, [FCR-1071], 29807, SLOT 4 | FID 2, INFO, Pluto, Port 6/22 is changed from non
FCR port to FCR port.
Using FC-FC Routing to Connect Fabrics
Brocade Fabric OS Administration Guide, 8.0.1
510 53-1004111-02