Reference Guide

751 3 31 7 ------ id 16G Online FC E-Port 10:00:00:05:1e:39:e4:5a
trunkmaster name (Trunk master)
This example shows the truncated output of the switchShow command for an FC16-32 port blade in slot 1 of a Brocade DCX 8510-8
Backbone. The Address column shows the PID.
switch:FID128:admin> switchshow -slot 1
switchName: DCX8510_8
(output truncated)
LS Attributes: [FID: 128, Base Switch: No, Default Switch: Yes, Address Mode 0]
Index Slot Port Address Media Speed State Proto
=======================================================================
0 1 0 500000 -- N16 No_Module FC
1 1 1 500100 -- N16 No_Module FC
2 1 2 500200 -- N16 No_Module FC
(output truncated)
This example shows the truncated switchShow output for an FC16-64 port blade on the Brocade DCX 8510 Backbone. The assignment
of port index numbers to PIDs will vary depending on blade type, platform type, and slot number.
DCX:admin> switchshow
Index Slot Port Address Media Speed State
=============================================================
0 1 0 0a0040 -- N16 No_Module
1 1 1 0a0140 -- N16 No_Module
2 1 2 0a0240 -- N16 No_Module
(output truncated)
768 1 48 0a00c0 -- N16 No_Module
769 1 49 0a01c0 -- N16 No_Module
770 1 50 0a02c0 -- N16 No_Module
(output truncated)
784 1 62 0a0ec0 -- N16 No_Module
783 1 63 0a0fc0 -- N16 No_Module
16 2 0 0a1040 -- N16 No_Module
17 2 1 0a1140 -- N16 No_Module
(output truncated)
This example shows the truncated switchShow output for an FX8-24 application blade on the Brocade DCX 8510-8 Backbone. The
assignment of port index numbers to PIDs will vary depending on blade type, platform type, and slot number.
switch:FID128:admin> switchshow -slot 10
switchName: my8510-8
(output truncated)
Slot Blade Type ID Model Name Status
--------------------------------------------------
10 AP BLADE 75 FX8-24 ENABLED
Index Slot Port Address Media Speed State Proto
=============================================================
80 10 0 505000 id 4G No_Light FC
81 10 1 505100 -- 4G No_Module FC
82 10 2 505200 id 4G Mod_Inv FC "Speed Mismatch / Incompatible SFP"
83 10 3 505300 -- 4G No_Module FC
84 10 4 505400 -- 4G No_Module FC
(output truncated)
95 10 15 505f00 -- -- Offline VE
208 10 16 50d000 -- -- Offline VE
209 10 17 50d100 -- 4G Offline VE
(output truncated)
Port Indexing
Brocade Fabric OS Administration Guide, 8.0.1
546 53-1004111-02