Setup Guide

Brocade Fabric OS Message Reference 131
53-1004119-01
AN-1011
5
AN-1011
Message Could not distinguish between primary and dependent severe latency bottleneck on
port <slotport string> because port mirroring is enabled on this port.
Message Type LOG | AUDIT
Class FABRIC
Severity WARNING
Probable Cause Indicates that resources that are needed to determine whether there is complete credit loss on a virtual
channel (VC) at the specified port are used by port mirroring.
Recommended
Action
Contact your switch service provider for assistance.
AN-1012
Message Credits did not return from other end. Complete loss of credits on a VC on port
<slotport string>.
Message Type LOG | AUDIT
Class FABRIC
Severity WARNING
Probable Cause Indicates a credit loss.
Recommended
Action
If this message is not followed by the AN-1013 message, contact your switch service provider for
assistance.
AN-1013
Message Performed link reset to recover the port credits on port <slotport string>.
Message Type LOG | AUDIT
Class FABRIC
Severity INFO
Probable Cause Indicates a credit loss.
Recommended
Action
The port is recovered. No action is required.