Setup Guide

Brocade Fabric OS Message Reference 191
53-1004119-01
C2-1032
5
C2-1032
Message S<slot number>,P<port number>(<blade port number>): Required buffer unavailable
for the port. req_buf:<required buffer> port_buf:<port buffer> unused_buf:<Unused
buffer> est_buf:<Estimated buffer>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that free buffers in the chip are not sufficient to bring the port online in fully operational mode.
The port may not come online or may operate in a degraded buffer mode.
Recommended
Action
If one or more ports that are configured as long distance in the chip are unused, reset these ports to
normal distance. If the problem persists, move the affected port to a different blade or chip.
C2-1033
Message Slow drain device quarantine (SDDQ) or Restore action is not completed for the sid
0x<Source ID>, did 0x<Destination ID>.
Message Type LOG
Severity INFO
Probable Cause Indicates that the Frame Transformation Block (FTB) entry is not added.
Recommended
Action
No action is required.