Message S<slot number>,P<port number>(<blade port number>): Internal CRC with good EOF
errors exceeded threshold, tuning is required. current:0x<last_crc_good_eof_cnt>,
last:0x<total_crc_good_eof_cnt> thresh2:0x<threshold_used>.
Message Type LOG
Severity WARNING
Probable Cause Indicates some CRC errors detected on backend link by hardware, applications may be affected.
Recommended
Action
If core blade reset, auto tuning or manual tuning did not resolve the issue, replace the blade.
C3-1031
Message LOSYNC timeout occured on Slot <slot number>, Port <port number>(<blade port
number>).
Message Type LOG
Severity INFO
Probable Cause Indicates that loss of synchronization has occurred on the BE port and link reset was invoked on this port
by the blade driver.
Recommended
Action
No action is required.
C3-1032
Message S<slot number>,P<port number>(<blade port number>): Required buffer unavailable
for the port. req_buf:<required buffer> port_buf:<port buffer> unused_buf:<Unused
buffer> est_buf:<Estimated buffer>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that free buffers in the chip are not sufficient to bring the port online in fully operational mode.
The port may not come online or may operate in a degraded buffer mode.
Recommended
Action
If one or more ports that are configured as long distance in the chip are unused, reset these ports to
normal distance. If the problem persists, move the affected port to a different blade or chip.