C4-1023
5
C4-1023
Message Single RDY/Frame Loss detected and recovered on Slot <slot number>,Port <port
number>(<blade port number>) rdy(0x<Credit Lost>)/frame(0x<Frame Lost>).
Message Type LOG
Severity WARNING
Probable Cause Indicates that above-normal errors are observed in hardware that may or may not impact the data traffic.
Recommended
Action
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.
C4-1028
Message Detected excessive Link resets on the port in a second. Slot <slot number>, Port
<port number>(<blade port number>).
Message Type LOG
Severity WARNING
Probable Cause Indicates that the port received excessive link resets from peer port within 1 second and that exceeded
the threshold.
Recommended
Action
When this error is observed persistently, change the small form-factor pluggable (SFP) transceiver or the
cable on the peer port to which this port is connected.
C4-1030
Message S<slot number>,P<port number>(<blade port number>): Internal CRC with good EOF
errors exceeded threshold, tuning is required. current:0x<last_crc_good_eof_cnt>,
last:0x<total_crc_good_eof_cnt> thresh2:0x<threshold_used>.
Message Type LOG
Severity WARNING
Probable Cause Indicates some CRC errors detected on backend link by hardware, applications may be affected.
Recommended
Action
If core blade reset, auto tuning or manual tuning did not resolve the issue, replace the blade.