Message Blade devices cannot be accessed. The blade in slot <FRU slot number> is being
moved to ABSENT state.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the devices on the blade were not accessible. Blade is being tranisitioned to the ABSENT
state.
Recommended
Action
Reseat or replace the affected blade.
EM-1074
Message The ASIC in <FRU ID> is overheating: Shutting down.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the ASIC present in switch is overheating and is beyond thermal operating range. This
event is typically due to a faulty fan and can also be caused by the switch environment.
Recommended
Action
Verify that the location temperature is within the operational range of the switch. Refer to the Hardware
Reference Manual for the environmental temperature range of your switch.
Execute the fanShow command to verify that all fans are running at normal speeds. If any fans are
missing or not performing at high enough speed, they should be replaced.
EM-1134
Message <FRU Id> set to faulty, rc=<return code>.
Message Type LOG | FFDC
Severity ERROR
Probable Cause Indicates that the specified field-replaceable unit (FRU) has been marked as faulty for the specified
reason.
Recommended
Action
Reseat the FRU.
Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power
cycle the blade by using the slotPowerOff and slotPowerOn commands or have the blade's ejector
switch cycled to run POST and verify that the blade does not have any hardware problems.
If the problem persists, replace the FRU.