Setup Guide

Brocade Fabric OS Message Reference 323
53-1004119-01
FABR-1051
5
FABR-1051
Message D-Port <Testname> test failed for slot <Slot> and port <Port>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the D_Port test failed for the given slot and port due to one of the following reasons:
The small form-factor pluggable (SFP) fault detected by electrical loopback test failure.
The cable fault detected by optical loopback test failure.
An application-specific integrated circuit (ASIC) issue detected by link traffic test failure.
Recommended
Action
Replace the faulty SFPs, cables, or blade.
FABR-1052
Message The configured port speed is invalid. Persistently disabling port <Port that is
being disabled>.
Message Type LOG
Severity INFO
Probable Cause Indicates that the configured speed for the specified port is invalid.
Recommended
Action
Execute the portCfgSpeed command to change the port speed.
FABR-1053
Message The switch is disabled due to an inconsistency found in the interop config
parameters.
Message Type LOG
Severity CRITICAL
Probable Cause Indicates that the configuration keys have interopmode parameters such as switch.interopMode and
switch.mcdtFabricmode set.
Recommended
Action
Execute the interopmode command to reset the parameters.