Setup Guide

444 Brocade Fabric OS Message Reference
53-1004119-01
HAM-1005
5
Fastboot
Giveup Master:SYSM
CP Faulty:SYSM
FirmwareDownload
ConfigDownload:MS
ChangeWWN:EM
Reboot:WebTool
Fastboot:WebTool
Software Fault:Software Watchdog
Software Fault:Kernel Panic
Software Fault:ASSERT
Reboot:SNMP
Fastboot:SNMP
Reboot
Chassis Config
Reboot:API
Reboot:HAM
EMFault:EM
Recommended
Action
Execute the errShow command on both control processors (CPs) to view the error log for additional
messages that may indicate reason for the switch restart.
HAM-1005
Message HeartBeat Miss reached threshold.
Message Type LOG
Severity INFO
Probable Cause Indicates that either the active CP Ethernet Media Access Controller (EMAC) or the standby CP is down.
The active CP will run a diagnostic test on EMAC and will wait for the standby CP to reset it if it is down.
Recommended
Action
No action is required.
HAM-1006
Message EMAC controller for Active CP is BAD.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the local Ethernet Media Access Controller (EMAC) on the active CP has been marked
BAD as determined by the diagnostic test run by the high avilability manager (HAM) module.