Brocade Fabric OS Message Reference 463
53-1004119-01
HIL-1511
5
HIL-1511
Message Fan speed of all the fan FRUs is increasing per environmental specifications.
Message Type LOG
Severity WARNING
Probable Cause Indicates that temperatures in the system have risen above the warning threshold and that the fan speed
is being increased.
Recommended
Action
Run the fanShow command to verify all the fans are working properly.
Make sure that the area is well-ventilated and that the room temperature is within the operational range
of your switch. Refer to the hardware reference manual for your switch for the operational temperature
range.
HIL-1512
Message High temperature (<measured temperature> C), Exceeds environmental
specifications.
Message Type LOG
Severity WARNING
Probable Cause Indicates that temperatures in the system have risen above the warning threshold.
Recommended
Action
Run the fanShow command to verify all the fans are working properly.
Make sure that the area is well-ventilated and that the room temperature is within the operational range
of your switch. Refer to the hardware reference manual for your switch for the operational temperature
range.
HIL-1513
Message Slot <slot number>, high temperature (<measured temperature>). Blade in the slot
will be shut down if temperature remains high.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the temperature of this blade has risen above the critical threshold. This usually follows a
high-temperature message.
Recommended
Action
Run the fanShow command to verify all the fans are working properly.
Make sure that the area is well-ventilated and that the room temperature is within operational range of
your switch. Refer to the hardware reference manual for your switch for the operational temperature
range.
If the message persists, replace the blade.