Setup Guide

466 Brocade Fabric OS Message Reference
53-1004119-01
HIL-1610
5
HIL-1610
Message Fan/PS unit <Combo fan/power supply unit number> not supplying power, fan speeds
may not be available. Please ensure that the unit has power and the switch is on.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the power supply is not connected to a power source, is not switched on, or the unit is
faulty. This message is applicable only to the Brocade 5100, 6505, 6510, 6520, and VA-40FC.
Recommended
Action
Ensure the power cord is connected to the unit with a valid power source and then switch on the unit (if
applicable). If the problem persists, try reseating the unit. If the problem still persists, replace the FRU.
HIL-1611
Message MISMATCH in PSU-FAN Air Flow direction. Replace PSU with fan air flows in same
direction. System will be shut down in 2 minutes.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the airflows of the power supply and fan assemblies are moving in the reverse or opposite
direction, which could overheat the system. The airflow of the power supply and fan assemblies must
move in the same direction or the system will shut down in two minutes. This message is applicable only
to the Brocade 6510.
Recommended
Action
Use the chassisShow command to check the airflow directions of the power supply and fan assemblies.
Ensure that the airflows run in the same direction.
HIL-1612
Message MISMATCH in PSU-FAN Air Flow direction. System shut down.
Message Type LOG
Severity CRITICAL
Probable Cause Indicates that the airflows of the power supply and fan assemblies are moving in the reverse or opposite
direction. The system will shut down immediately. This message is applicable only to the Brocade 6510.
Recommended
Action
Ensure that the airflows of the power supply and fan assemblies run in the same direction.