Setup Guide

472 Brocade Fabric OS Message Reference
53-1004119-01
HLO-1001
5
HLO Messages
HLO-1001
Message Incompatible Inactivity timeout <dead timeout> from port <port number>, correct
value <value>.
Message Type LOG | FFDC
Severity ERROR
Probable Cause Indicates that the hello (HLO) message was incompatible with the value specified in the fabric shortest
path first (FSPF) protocol. The Brocade switch will not accept FSPF frames from the remote switch.
In Fabric OS, the HLO dead timeout value is not configurable, so this error can only occur when the
Brocade switch is connected to a switch from another manufacturer.
Recommended
Action
The dead timeout value of the remote switch must be compatible with the value specified in the FSPF
protocol. Refer to the documentation for the other manufacturer's switch to change this value.
HLO-1002
Message Incompatible Hello timeout <HLO timeout> from port <port number>, correct value
<correct value>.
Message Type LOG | FFDC
Severity ERROR
Probable Cause Indicates that the hello (HLO) message was incompatible with the value specified in the fabric shortest
path first (FSPF) protocol. The Brocade switch will not accept FSPF frames from the remote switch.
In Fabric OS, the HLO timeout value is not configurable, so this error can only occur when the Brocade
switch is connected to a switch from another manufacturer.
Recommended
Action
The HLO timeout value of the remote switch must be compatible with the value specified in the FSPF
protocol. Refer to the documentation for the other manufacturer's switch to change this value.